What it detects

Twelve measurements. A dozen things worth knowing.

None of these needs extra hardware. They all fall out of readings the sensor takes anyway, every three seconds.


Party detection

A party has a signature. Two people watching television doesn't.

A single loud noise isn't a party — it's a dropped suitcase. What matters is the pattern, and the sensor watches four things at once so you're not woken by a false alarm.

Room 214 23:47
34dBA
Quiet — normal night-time level
20alert at 7090
Sustained above threshold — 11 minutes.
Radar reports multiple moving targets. CO₂ 1,840 ppm, rising. Notification sent to duty manager 23:47.
This is a number, not a recording. Nothing here can be played back.
  • Sound level — sustained above your threshold, not one spike
  • Occupancy — radar sees several moving targets, not one
  • CO₂ — climbs fast and hard when a room holds far more people than it was let to
  • Time of night — your quiet hours, your rules

CO₂ is the one operators don't expect and end up relying on most. A room booked for two, holding fifteen, gives itself away in the air long before it gets loud — which buys you the chance to make a quiet phone call instead of arriving to a problem.

Typical CO₂ after two hours in a sealed double room
alert · 1,400 ppm 2 guests 700 ppm 4 guests 1,150 ppm 8 guests 1,900 ppm 15 guests 2,900 ppm Indicative — 22 m³ room, window shut, ventilation off.
A party has a shape. Sustained level rather than a single spike, several moving targets, and CO₂ climbing hard as the room fills well past the booking.
22:10 · Room 214
36 dBA · 2 occupants · CO₂ 610 ppm. Normal. Nobody is notified.
23:02
One spike to 78 dBA, lasting 4 seconds. Ignored — a door, not a party.
23:36
71 dBA sustained. CO₂ passes 1,400 ppm. Radar reports multiple movers. Watch condition opened.
23:47
Eleven minutes sustained. Duty manager notified with the room number, the level and the trend. One phone call, before the neighbours ring reception.
00:20
42 dBA. Resolved. The whole night is logged with timestamps — which is what you need if a deposit claim follows.
Twenty-four hour history: an occupancy bar showing when the room was occupied and clear, above a sound level trace across the same period.
The evidence, not the anecdote. Occupancy and sound on the same 24-hour axis. When a guest disputes a noise charge, this is the screen you send them — and it contains no recording for anyone to demand.

The signature, not the smell. Volatile compounds and particulates rise together and decay over twenty minutes — a shape a shower or an aftershave never makes.
Room 214 · particulates and volatile compounds · 02/09/2026, 21:00 – 21:30
highclear 21:14 · inspection flagged 21:00 21:14 21:30
Volatile compounds Particulates Threshold crossed
Air quality gauges: AQI 72, CO₂ 583 ppm, breath VOC 0.68 ppm, particulates 8.4 µg/m³ — all reading in or near the green band.
The two gauges that catch it. Breath VOC and particulates, shown here on a clean room. A smoking event pushes both needles into the red together, then lets them fall back slowly — a shape nothing else in a bedroom produces.

Smoking and vaping

The £250 cleaning fee you currently never collect.

Almost every operator has a no-smoking policy and a fee attached to it. Almost none of them ever charge it, because by the time housekeeping smells the room the guest has checked out and the argument is unwinnable.

Smoking and vaping both produce a sharp, unmistakable signature: volatile compounds and airborne particulates spiking together, then decaying slowly over twenty minutes. A shower doesn't look like that. Nor does aftershave, or a takeaway.

You find out at 21:14, not at 11:00 the next morning. Which means a polite phone call while the guest is still in the building, and a fee raised against a timestamped record rather than a housekeeper's word.

Be precise about what this proves. The sensor detects an aerosol event in the room — it does not chemically identify tobacco, cannabis or a vape, and we would not advise selling it as if it did. What it gives you is a reliable, timestamped trigger to inspect and to act. That is the difference between a fee you can raise and one you can't.

Intruder detection · unoccupied rooms

Nobody is booked into 214. Somebody is in it.

Every operator has rooms standing empty — taken off sale, waiting for a repair, turned over between lets, or a whole property sitting vacant for a fortnight. Nobody looks at them. That is exactly why they're the ones worth watching, and why an empty room is the easiest place in the building to detect somebody who shouldn't be there.

Tell Pulse which rooms are supposed to be empty, and presence in one of them becomes an alert rather than a reading. It works in the dark, through a closed door, and picks up someone lying still — because it's radar, not a motion detector and not a camera.

What it actually catches: a guest who checked out yesterday and came back, a key handed to somebody it shouldn't have been, a contractor in a room at 23:00, a door left on the latch, someone sleeping in a unit between lets. For a host managing a property eighty miles away, that's the difference between finding out now and finding out at the next changeover.

It's the same radar doing the same job as everywhere else on this page. You're simply inverting the question: instead of "is anyone here, so I can save energy", it's "is anyone here, because there shouldn't be".

Three things to be straight about.

It tells you someone is there, not who. A guest, a cleaner, a contractor and an intruder all look identical to a radar. Always read it against your bookings and your rota before you act on it — and never treat it as identification.

This is the one feature siting can ruin. 24 GHz radar reads through plasterboard. Mount a unit badly against a stud partition and it will report your neighbour's room as an intrusion. Gate the detection distance at commissioning; it takes a minute per room and it is not optional for this use.

It is not a security system. Pulse isn't a graded intruder alarm, it doesn't summon anybody, and it isn't monitored. It's an alert to your phone. Also worth knowing: if you point it at staff movements rather than empty rooms, that becomes employee monitoring under UK GDPR and needs an assessment first.
Vacant on the chart, occupied in fact. The distance figure is what separates a real intrusion from a reading bleeding through a stud partition.
Floor 2 · expected state versus what the radar reports · 02/09/2026, 23:12
210
Booked · occupied
As expected
211
Booked · occupied
As expected
212
Vacant · clear
As expected
213
Out of service · clear
As expected
214
Vacant · presence detected
Check this room
215
Booked · arriving 18:00
As expected

Five rooms behaving. One that isn't. The board only ever asks you to look at the exception — which is the only way a hundred rooms stays manageable.

Presence panel: in the room — detected; distance — 208 cm; movement — detected; still person — detected.
Distance is the detail that makes this work. 208 cm puts the person inside the room rather than beyond the wall — which is how you gate out a false alarm from next door.

Rate of temperature rise

A room getting hot fast, in a building where nobody is looking.

A smoke alarm waits for smoke to reach the ceiling and enter the chamber. Temperature starts moving earlier — and Pulse reads the room every three seconds, so it sees the gradient, not just the value.

A room climbing 6 °C in four minutes with nobody in it is not a warm afternoon. Neither is a vacant room at 2 am rising steadily. You get told, with a room number, while it is still a question rather than an evacuation.

The practical value is in the rooms nobody enters for days: out-of-service rooms, plant cupboards, void units between lets, a laundry room with a tumble dryer in it.

This is not a fire alarm, and must never be sold as one. Pulse is not EN 54 certified, is not a heat or smoke detector, and is not a substitute for the fire detection and alarm system your premises is legally required to maintain under the Regulatory Reform (Fire Safety) Order 2005. It must not appear in your fire risk assessment as detection provision, and it will not summon the fire service.

What it is: a supplementary operational alert that may reach you before a certified system triggers. Treat it as extra warning on top of a compliant system — never as a reason to fit fewer alarms.
Gradient, not temperature. A room nobody has entered for days, climbing 1.8 °C a minute. A supplementary alert — never a replacement for a certified fire system.
02:14 · Room 09, out of service
19.2 °C, unoccupied, stable for six hours. Nothing happening.
02:18
21.0 °C. Rising, but slowly. Below the gradient threshold — no alert. A warm night does this.
02:21
26.4 °C. Rate of rise 1.8 °C per minute in an empty room, with volatile compounds climbing alongside it. Alert raised.
02:22
Night porter has a room number and a reason to walk down there — before the ceiling detector has anything to work with.
Device panel: WiFi signal −44 dBm, online and connected, air quality calibration 1, uptime 2,225 seconds.
Every unit reports its own health. Signal strength, uptime and a live heartbeat — so a sensor that has dropped off the network tells you, rather than quietly watching nothing across a hundred rooms.

Damp and water damage

The leak you find in August started in March.

The expensive water damage in a let property is almost never the dramatic kind. It's the slow kind — an extractor fan that stopped working, a shower seal that went, a pipe weeping inside a wall — quietly turning a room into a mould problem across a whole season.

Pulse watches humidity and temperature continuously and tells you when a room stops drying out. A bathroom that hits 85% after a shower is normal. A bedroom sitting above 70% for three days in a row is not, and it will be a redecoration bill by the autumn.

You get told in March. A £40 fan, instead of a stripped wall, a replastering job and three weeks of a room you can't sell.

Said plainly: Pulse is not a flood alarm and has no water contact — it will not tell you a pipe has burst this minute. What it detects is the humidity signature of a room that is getting damp and staying damp. For catastrophic leaks, pair it with a leak detector under the basin; the two answer different questions.
The room that stops drying out. Humidity spikes after every shower and never returns to baseline — the fan has failed, months before anything is visible on a wall.
Room 07 · relative humidity · 01/03/2026 – 28/03/2026
9080 706050 alert · 70% 19/03 notified 01/03 08/03 28/03
Relative humidity Sustained-damp threshold
Comfort gauges: temperature 27.5 °C, humidity 41 percent, sound 34 dBA.
Humidity, banded both ways. Below 30% is too dry and cracks the joinery; above 60% is where damp starts. Only the middle is green — which is why the same gauge answers a guest comfort question and a building maintenance one.

Nine more things the same box tells you

Most of these only became obvious once operators had one running.

None of them needs extra hardware. They fall out of measurements the sensor is taking anyway.

Proof the room was actually cleaned
particulates + volatile compounds + presence

A real clean has a signature: someone in the room for twenty minutes, dust lifted into the air, cleaning products in the volatile reading. No signature between two bookings means nobody cleaned it. If you manage remotely and pay a cleaner you never see, this one alone justifies the sensor.

Air conditioning that has quietly failed
infrared command + temperature response

Pulse commands the unit and then watches whether the room actually responds. Cooling called for, temperature flat for thirty minutes — the unit is broken. You know on Tuesday instead of finding out through a Saturday complaint and a refunded night.

Extractor fan failure
humidity decay

Humidity spikes after a shower and then doesn't come back down. The fan has died, months before the damp shows on a wall.

Frost and burst-pipe risk
°C, falling

A vacant unit dropping towards freezing in January. The cheapest water damage is the kind that never happens.

Window open, heating on
°C + humidity

Heating running hard while the room refuses to warm. Money leaving through a sash window.

Lights burning in an empty room
lux + radar

Light level high, nobody present, for hours. Small money on one room, real money across a hundred.

Which rooms are free right now
radar

Housekeeping stops knocking on occupied doors. Rooms get turned in the order they're actually available.

More guests than the booking
CO₂ + radar

A room let to two, slept in by six. The air says so within an hour, long before the party rule would ever fire.

Why that room keeps getting three-star reviews
portfolio comparison

Across a hundred rooms, patterns surface that no individual complaint reveals: the four rooms that never get below 24 °C in summer, the two beside the lift that run 8 dBA louder all night, the one that sits at 68% humidity year-round. That's a capital plan built on measurements rather than on which guest shouted loudest.

Rooms that are stuffy enough to cost you a review
CO₂ overnight

A sealed room with two people in it climbs past 1,500 ppm by 3 am. Guests rarely blame the air — they write "didn't sleep well" and give you four stars. Ventilate on a threshold and the complaint stops arriving.


One device

Twelve measurements, updated every few seconds.

No camera. No microphone recording. Nothing with a lens and nothing with a memory of anyone's voice.

Summary tiles: temperature 27.5 °C, humidity 41 percent, CO₂ 583 ppm, noise 34 dBA, occupancy detected, light 79 lx, air quality 72, pressure 1,019 hPa.
The whole room in one strip. This is the top of every room's page. Eight readings, a glance, no interpretation required — which is the difference between a system staff use and one they stop opening after a fortnight.
Sound level
dBA · A-weighted

Loudness only. The measurement your party rule runs on, and the one that cannot be turned back into speech.

Occupancy
24 GHz radar

Detects a still, breathing person in the dark. No lens, no image.

Distance to person
cm

Tells a person in the room from movement in the corridor.

Temperature
°C

Comfort complaints, and frost risk in an empty property.

Humidity
% RH

The damp early-warning trace. Your most valuable long-run reading.

CO₂ equivalent
ppm

How many people are really in the room, and whether the ventilation is coping. Rises fast during an overcrowded party and stays flat during a quiet evening.

Air quality index
AQI

A single overall figure for how the room's air is doing.

Volatile compounds
ppm

Aerosols, solvents, cleaning products — and stale, unaired rooms.

Particulates
µg/m³ · optional

Smoke and dust, on units fitted with the particle module.

Light level
lux

Lights left burning in a room nobody is in.

Air pressure
hPa

Weather context for the heating and cooling logic.

Peak sound
amplitude

Separates one slammed door from a sustained disturbance.

Infrared out and in
transmit · learn

Controls the air conditioning and television you already own, and learns their codes from your existing remote in one pass.


Availability

Coming soon.

Pulse is in final testing ahead of its first hundred-room rollout. Leave your details and we'll be in touch when units are available — with a live dashboard, a walk through exactly what is and isn't captured, and a rollout costed against the numbers you put in above.